If you prefer to download the Permitex Test Sheets file, please
click here. This file is in
Adobe Acrobat format. You need the Adobe Acrobat reader to open
this file. Download the Acrobat Reader here.
SGS U.S. Testing Company, Inc.
Report Number: 115518
Date: 11/06/98
Results:
Scrubbability
ASTM D-2486
# Cycles to Failure
Panel 1 38,800 cycles
Panel 2 36,800 cycles
Pencil
Hardness Hardness
ASTM D-3363
Rating = H
Rating Scale: Softest 4B-3B-2B-B-HB-H-3H-4H Hardest
Scrape
Adhesion Adhesion Failure End Point
ASTM D-2197
3.5 Kg
Water
Vapor
ASTM E-96
| WVT (g/m2/24h) |
26.184 |
25.418 |
25.485 |
| WVT (grain/ft2/1h) |
1.515 |
1.471 |
1.694 |
| WVT (g/m2/24h/mn.Hg) |
2.397 |
2.327 |
2.681 |
| WVP (grain/ft2/h/in.Hg) |
3.523 |
3.420 |
3.940 |
Professional
Service Industries, Inc
Omega Point Labratories
Report # 12640-97068
Date: 6/26/94
Results:
Fire
& Smoke
ASTM E84-91A
Permitex
is non-combustible and substantially exceeds the standards for type
1 class A materials. Permitex contributed results of zero (0) for
flame spread and five (5) for smoke developed when compared to the
results for the underlying wall board substrate.
Lancaster
Laboratories
Date: 5/12/94
Results:
Mildew
Resistance
Cat No. 1325
After
seven days of incubation, 0% of the surface of the sample was covered
with mold growth. The surface of the control plate was completely
covered with mold growth. There was a 7 to 10 mm zone of inhibition
of the mold around the sample.
|